RF-257 Cemseal 501
500% Elongation Waterproof System
1. The surface must be structurally sound, dry, free of dust, grease and other loose contaminants.
2. Apply 1 coat of RHINOZ Primer Bonding on the desired area, and apply it on boundary wall up to 10-20cm above ground level and let it dry for 30-60 minutes.
3. Mix RHINOZ CemSeal 501 by low speed mixer and stir until homogeneous before use.
4. Apply 3 coats of RHINOZ CemSeal 501 by brush or roller, allow it to dry for 2-4 hours.
5. In case of reinforcing the application area such as wall/floor junctions or corners. It is advised to put the fiberglass mesh tape and roll immediately into the 1st coat of RHINOZ CemSeal 501, allow to dry for 2-4 hours.
6. Apply the 2nd coat over the fiberglass mesh tape ensuring that all of the fiberglass mesh tape
is covered, allow for 2-4 hours and then apply the 3rd coat.
7. Allow it to completely dry for 7 days before tiling or filling water and water tanks must be rinsed thoroughly prior to filling.